Responsible Technicians of SCIE – Water extinguishing systems – Specific Training

TRAINING TEAM

TO BE DETERMINED
training category
Join our training!
Mandatory training for all technicians responsible for the commercialization, installation, or maintenance of fire safety equipment and systems in buildings, who wish to register with ANEPC. Ordinance No. 686/2023, dated January 13.
280
Duration:
28h
Mode:
B-Learning
Goals: The aim of this course is to enable trainees to register with ANEPC as Responsible SCIE Technicians, and provide them with knowledge in the area of ​​marketing, installation and maintenance of fire safety products and equipment in buildings. Duration: 28hours Target Audience: Professionals/Technicians who carry out their activities within the scope of Fire Safety in Buildings; Security Managers and Delegates; Occupational Safety Technicians; Security Consultants; Designers; Inspection Agents; All those interested in the area of ​​Fire Safety in Buildings; Certification: Successful completion grants the trainee a Professional Training Certificate issued on the SIGO platform. The issuance of the certificate on the aforementioned platform allows the automatic crediting of skills to the trainee's Qualifica Passport. Training team: To be announced Additional information: Start date: To be announced Value: 280€ Regime: B-Learning Modules Module 1 – Regulatory requirements, namely the SCIE Technical Regulation, ANEPC technical notes, standards, as well as other technical specifications and applicable legislation. Module 2 – Elementary physical notions of hydraulics. Module 3 – Flow in pipes. Module 4 - Flow rate, expression that relates the flow rate to the average flow speed and the pipe section, units. Module 5 - Flow pressure along the pipe, units, manometric height. Module 6 - Bernoulli's Theorem. Module 7 - Altimetric pressure losses, continuous and localized, units. Load loss abacuses. Module 8 - Equivalent length of plumbing accessories, to calculate load losses in the network. Module 9 - Static pressure and dynamic pressure in a piping network. Module 10 - Discharge coefficient K of fire hydrants and sprinklers. Module 11 - Calculation expression of the flow rate delivered by a fire hydrant or sprinkler, depending on the pressure affected by the discharge coefficient, units. Module 12 - Definitions. Module 13 - Outdoor Hydrants Types of Hydrants. Module 14 - Specifications of Fire Landmarks. Module 15 - Specifications for facade or buried Fire Hydrants. Module 16 - Protection and signaling of hydrants. Module 17 - Powering hydrants. Module 18 - Fire Mark Installation Requirements. Module 19 - SCIE RT Requirements for Outdoor Fire Hydrants. Module 20 - Maintenance Procedures. Module 21 - Water curtains System description. Module 22 - Diffusers. Module 23 - SCIE RT Requirements. Module 24 - Installation requirements. Module 25 - Maintenance Procedures. Module 26 - Dry and wet networks Description and characterization of dry and wet networks. Module 27 – Requirements of the technical regulation for fire safety in buildings. Module 28 – Installation and maintenance of Dry, Wet and BIA Networks. Module 29 – Automatic Water Fire Extinguishing Systems Configurations of automatic water fire extinguishing systems. Module 30 – Requirements of the technical regulation for fire safety in buildings. Module 31 – Type of Sprinklers. Module 32 – Installation, operation and maintenance of Systems. Module 33 – Water Supply for the SI Module 34 – Pumping Plants for the SI. Module 35 – Water supply sources for the IS. Module 36 – Piping to be used in the Fire Service. Module 37 – Installation and maintenance of Pumping Plants. Module 38 – Flow in pipes .

DESCRIPTION

Mandatory training for all technicians responsible for the commercialization, installation, or maintenance of fire safety equipment and systems in buildings, who wish to register with ANEPC. Ordinance No. 686/2023, dated January 13.

AIM

The basic training aims to qualify trainees for their registration with ANEPC as Technicians Responsible for Fire Safety in Buildings and provide them with knowledge in the commercialization, installation, and maintenance of fire safety products and equipment in buildings.

TARGET

  • Profissionais / Técnicos que desenvolvam a sua atividade no âmbito da Segurança Contra Incêndio em Edifícios;
  • Responsáveis e Delegados de Segurança;
  • Occupational Safety Technicians;
  • Security Consultants;
  • Designers;
  • Inspection Agents;
  • Todos os interessados pela área da Segurança Contra incêndio em Edifícios;
  • Certification

Certification

  • A conclusão com aproveitamento confere ao formando um Certificado de Formação Profissional emitidos na plataforma SIGO.
  • A emissão do certificado na referida plataforma, permite a creditação automática das competências no Passaporte Qualifica do formando.

module 1

Regulatory requirements, including the Fire Safety in Buildings Technical Regulation (Regulamento Técnico de SCIE), technical notes from the ANEPC, standards, as well as other applicable technical specifications and legislation.

module 2

Basic physical concepts of hydraulics.

module 3

Flow in pipelines.

module 4

Flow rate, an expression that relates the flow rate to the average velocity of the flow and the cross-sectional area of the pipe, and units.

module 5

Flow pressure along the pipeline, units, and manometric height.

module 6

Bernoulli's Theorem.

module 7

Head losses: elevation, continuous, and localized losses, units. Head loss charts.

module 8

Equivalent length of pipe fittings, for calculating head losses in the network.

module 9

Static pressure and dynamic pressure of a piping network.

module 10

Discharge coefficient K of fire hydrants and sprinklers.

module 11

Calculation expression for the flow discharged by a fire hydrant or sprinkler, based on the pressure and the discharge coefficient, units.

module 12

Definitions.

module 13

Exterior Hydrants – Types of Hydrants.

module 14

Specifications of Fire Hydrants.

module 15

Specifications for Facade or Underground Fire Hydrants.

module 16

Protection and signaling of fire hydrants.

module 17

Hydrant supply.

module 18

Fire Hydrant Installation Requirements.

module 19

Requirements of the SCIE Technical Regulation for Exterior Hydrants.

module 20

Maintenance Procedures.

module 21

Cortinas de água Descrição do sistema.

módulo 22

Difusores.

módulo 23

Exigências do RT de SCIE.

módulo 24

Requisitos de instalação.

módulo 25

Maintenance Procedures.

módulo 26

Redes secas e húmidas Descrição e caracterização de redes secas e húmidas.

módulo 27

Requisitos do regulamento técnico de segurança contra incêndio em edifícios.

módulo 28

Instalação e manutenção de Redes Secas, Húmidas e BIA.

módulo 29

Sistemas Automáticos de Extinção por água Configurações dos sistemas automáticos de extinção de incêndios por água.

módulo 30

Requisitos do regulamento técnico de segurança contra incêndio em edifícios.

módulo 31

Tipo de Sprinklers.

módulo 32

Instalação, exploração e manutenção de Sistemas.

módulo 33

Abastecimento de Água para o SI

módulo 34

Centrais de Bombagem para o SI.

módulo 35

Fontes Abastecedoras de água para o SI.

módulo 36

Tubagens a utilizar no Serviço de Incêndio.

módulo 37

Instalação e manutenção de Centrais de Bombagem.

módulo 38

Escoamento em tubagens

Trainee
testimonies

The opinion of our trainees is very important to us, as it allows us to improve as a training entity and provide the best service to our clients / trainees.

training courses
mais vendidos