Goals: The aim of this course is to enable trainees to register with ANEPC as Responsible SCIE Technicians, and provide them with knowledge in the area of marketing, installation and maintenance of fire safety products and equipment in buildings. Duration: 28hours Target Audience: Professionals/Technicians who carry out their activities within the scope of Fire Safety in Buildings; Security Managers and Delegates; Occupational Safety Technicians; Security Consultants; Designers; Inspection Agents; All those interested in the area of Fire Safety in Buildings; Certification: Successful completion grants the trainee a Professional Training Certificate issued on the SIGO platform. The issuance of the certificate on the aforementioned platform allows the automatic crediting of skills to the trainee's Qualifica Passport. Training team: To be announced Additional information: Start date: To be announced Value: 280€ Regime: B-Learning Modules Module 1 – Regulatory requirements, namely the SCIE Technical Regulation, ANEPC technical notes, standards, as well as other technical specifications and applicable legislation. Module 2 – Elementary physical notions of hydraulics. Module 3 – Flow in pipes. Module 4 - Flow rate, expression that relates the flow rate to the average flow speed and the pipe section, units. Module 5 - Flow pressure along the pipe, units, manometric height. Module 6 - Bernoulli's Theorem. Module 7 - Altimetric pressure losses, continuous and localized, units. Load loss abacuses. Module 8 - Equivalent length of plumbing accessories, to calculate load losses in the network. Module 9 - Static pressure and dynamic pressure in a piping network. Module 10 - Discharge coefficient K of fire hydrants and sprinklers. Module 11 - Calculation expression of the flow rate delivered by a fire hydrant or sprinkler, depending on the pressure affected by the discharge coefficient, units. Module 12 - Definitions. Module 13 - Outdoor Hydrants Types of Hydrants. Module 14 - Specifications of Fire Landmarks. Module 15 - Specifications for facade or buried Fire Hydrants. Module 16 - Protection and signaling of hydrants. Module 17 - Powering hydrants. Module 18 - Fire Mark Installation Requirements. Module 19 - SCIE RT Requirements for Outdoor Fire Hydrants. Module 20 - Maintenance Procedures. Module 21 - Water curtains System description. Module 22 - Diffusers. Module 23 - SCIE RT Requirements. Module 24 - Installation requirements. Module 25 - Maintenance Procedures. Module 26 - Dry and wet networks Description and characterization of dry and wet networks. Module 27 – Requirements of the technical regulation for fire safety in buildings. Module 28 – Installation and maintenance of Dry, Wet and BIA Networks. Module 29 – Automatic Water Fire Extinguishing Systems Configurations of automatic water fire extinguishing systems. Module 30 – Requirements of the technical regulation for fire safety in buildings. Module 31 – Type of Sprinklers. Module 32 – Installation, operation and maintenance of Systems. Module 33 – Water Supply for the SI Module 34 – Pumping Plants for the SI. Module 35 – Water supply sources for the IS. Module 36 – Piping to be used in the Fire Service. Module 37 – Installation and maintenance of Pumping Plants. Module 38 – Flow in pipes Extintores.
“Lorem ipsum dolor sit amet, consectetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt ut laoreet dolore magna aliquam erat volutpat.”
“Lorem ipsum dolor sit amet, consectetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt ut laoreet dolore magna aliquam erat volutpat.”
“Lorem ipsum dolor sit amet, consectetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt ut laoreet dolore magna aliquam erat volutpat.”
Rua Quinta D'El Rei, Loja 3 3500-401 Viseu
232 437 098*
969 329 373 **
960 444 870 **
* chamada para rede fixa nacional
** chamada para rede móvel nacional
Rua Quinta D'El Rei, Loja 3 3500-401 Viseu
232 437 098*
969 329 373 **
960 444 870 **
* chamada para rede fixa nacional
** chamada para rede móvel nacional